PROJECT OVERVIEW DANA POINT, CA
4-ton Carrier heat pump. Three zones retained.
The homeowner was remodeling the side yard and wanted a smaller outdoor unit without losing the home’s three-zone layout. MaksBuilder replaced the three-year-old furnace and AC with a Carrier inverter heat pump and updated the zone controls.
- Location
- Capistrano Beach, Dana Point, CA
- Completed
- July–August 2026
- Equipment
- Carrier 37MUHA outdoor unit + 45MUHA air handler

- System capacity
- 4 tons
- Comfort zones
- 3 zones
- Conversion
- Gas → electric
- Refrigerant
- R-454B
Variable-speed inverter
Existing duct zones retained
Heating and cooling
Carrier Puron Advance
01 / THE CHALLENGE
Why replace a three-year-old system?
The existing ACPro furnace and AC were only three years old. The homeowner reported uneven airflow between rooms, and the box-style condenser took up space needed for a side-yard remodel.
The outdoor unit needed to fit the side-yard layout. We could keep the existing zoned ductwork, but the control board needed replacement for the new equipment.
02 / EQUIPMENT SELECTION
System selection
We paired the 4-ton Carrier Performance 19 Crossover outdoor unit (37MUHA) with a Performance Crossover air handler (45MUHA) to fit the available space and existing duct layout.
Slim side-discharge cabinet
Its compact profile suited the planned side-yard remodel better than the previous box-style condenser.
Inverter operation
The compressor adjusts capacity as heating and cooling demand changes, rather than using a single fixed output.
Existing ductwork
The zoned ductwork stayed in place. We installed a new zone-control board and checked each zone.
The system uses R-454B. Its exact SEER2/HSPF2 rating requires the AHRI certificate for the installed equipment combination.
03 / THE INSTALLATION
Installation scope
Gas-to-electric conversion, air-handler connections, outdoor installation and commissioning of all three zones.
- 01
Remove existing equipment
Removed the ACPro furnace, evaporator coil and condenser and hauled them away. Capped and sealed the gas supply and the old furnace flue.
- 02
Adapt indoor connections
Installed the Carrier air handler on the existing garage platform with supply-plenum transitions, a condensate drain and trap, and a filter cabinet.
- 03
Install outdoor heat pump
Set the slim outdoor unit on a level pad with a new disconnect and electrical whip. Pressure-tested the refrigerant lines with nitrogen, performed a triple vacuum and charged the system with R-454B.
- 04
Commission and test zones
Verified charge in heating and cooling, tested safety controls, and measured static pressure, airflow and temperature split. Checked all three zones and explained the zone controls and filter schedule to the homeowner.


04 / THE RESULT
Compact outdoor installation, existing ductwork retained
The new side-discharge unit fits beside the remodeled wall, and the home’s existing zoned ductwork remains in service. A single electric heat pump now handles heating and cooling.
COMMISSIONING
Checked on site
Refrigerant charge, static pressure, airflow, zone controls, and heating and cooling operation.
PHOTO DOCUMENTATION
Installation photos



EQUIPMENT & JOB RECORD
Installed equipment
- Outdoor heat pump
- Carrier Performance 19 Crossover, model 37MUHA, 4-ton inverter
- Indoor air handler
- Carrier Performance Crossover, model 45MUHA
- Zoning
- Existing three-zone ductwork retained; new zoning control board
- Refrigerant
- R-454B (Puron Advance)
- Equipment removed
- Three-year-old ACPro gas furnace and air conditioner; gas supply and old flue sealed
- Place / timing
- Capistrano Beach, Dana Point · July–August 2026
Efficiency rating: Carrier lists up to 19 SEER2 cooling and 10.8 HSPF2 heating for the product family. The AHRI-certified rating for this exact installed combination has not yet been verified; those maximum figures are not presented as this project’s measured efficiency.
PLANNING YOUR OWN UPGRADE?
Planning a heat pump upgrade?
Free in-home installation estimates in Dana Point and South Orange County. Licensed California HVAC contractor · CSLB #1095368.