MaksBuilder project · Daikin FIT heat pumps · Mission Viejo
A well-researched homeowner came to us with a detailed spec. We replaced both Carrier gas furnace and R-22 AC systems with two Daikin FIT inverter heat pumps, communicating variable-speed air handlers and MERV 15 media air cleaners, rebalanced the upper-floor airflow after a bedroom remodel, and passed HERS verification on the first try, all while the Daikin rebates were still available.
- 2 systems: 1st floor + 2nd/3rd floors, 3.5 and 4 tons
- 19 SEER2: up to, inverter-driven Daikin FIT
- HERS passed: first try, duct leakage verified
- MERV 15: media air cleaner on both systems
The situation
The homeowners of a three-story single-family home in Mission Viejo (92692) had two Carrier split systems, each more than 20 years old: a 3.5-ton system for the first floor and a 4-ton system for the second and third floors. Both used R-22, a refrigerant that is no longer produced, so any repair involving refrigerant would be expensive. The downstairs system was no longer keeping up. They had done their homework and sent us a detailed request:
- Daikin FIT R-32 inverter heat pumps with matched, communicating variable-speed air handlers.
- Smart thermostats and deep-pleated media filtration in place of the thin 1-inch filters at the return grilles, to clean the air better and reduce static pressure.
- Line-set flushing, nitrogen purge and proper evacuation; a City of Mission Viejo permit; Title 24 HERS duct leakage verification.
- An itemized proposal with two options: replace only the first-floor system, or replace both systems together.
- An airflow review during the site visit: a second-floor remodel had moved a main supply register for the upper zone into a remodeled bedroom.
Our recommendation
During the walkthrough we inspected both systems, the attic air handler locations, the return air
setup and the supply runs to the second and third floors, and we gave the homeowners the itemized two-option proposal they asked for. They chose to replace both systems at once: with two systems of the same age on R-22, doing both together meant one permit, one HERS visit, a bundle discount and both systems covered by the Daikin rebate.
- First floor: Daikin FIT 3.5-ton heat pump (DH6VSA series) with a Daikin DFVE communicating variable-speed air handler.
- Second and third floors: Daikin FIT 4-ton heat pump (DH6VSA series) with a matched Daikin DFVE air handler.
- Why FIT: the inverter compressor matches its output to the home’s load instead of cycling on and off, for efficiency up to 19 SEER2, steadier temperatures from floor to floor and quiet operation. A heat pump also replaces the gas furnaces, so each system now heats and cools.
- Filtration: a Daikin One Premium Air Cleaner at each air handler: a deep MERV 15 media cabinet that captures more than 85% of particles down to 0.3 microns at rated airflow, with a catalyst insert that helps remove formaldehyde and ozone. The deep media also has much less airflow resistance than a dense 1-inch filter.
- Airflow fix for the remodel: the walkthrough confirmed the upper zone’s airflow was out of balance after the remodel moved a main supply into one bedroom. The fix was a new supply plenum with balancing dampers on the upper-floor system, so air could be split properly between the second and third floors.
- Controls: a Daikin One Touch smart thermostat for each system. It communicates with the FIT equipment, and the Daikin One Home app adds scheduling and remote control from anywhere.
The installation
- Removed both old furnaces, coils and condensers; cut, capped and sealed the gas supply and removed the old flue venting per code.
- Set both Daikin air handlers in the attic on level platforms with secondary drain pans; new supply and return plenums, transitions and air cleaner cabinets, all sealed with mastic and mechanical fasteners.
- Overflow protection: float safety switches on the primary drains and on the secondary pans, a must for attic equipment over finished ceilings.
- Line sets: after inspection for size and condition, the existing line sets were chemically flushed to remove old R-22 mineral oil and contaminants, then blown dry with nitrogen; new filter driers; all brazing done with nitrogen flowing.
- Rebalanced the upper zone: built and installed a new supply plenum with manual balancing dampers, then adjusted them so the remodeled bedroom no longer takes more than its share and the third floor gets enough air.
- Both FIT heat pumps placed on new pads with new disconnects and electrical whips; breaker and wire sizes checked against the new equipment.
- Commissioning: nitrogen standing pressure test, triple evacuation to below 500 microns with a decay test, charge weighed in and verified in heating and cooling, all safety controls tested, including the R-32 refrigerant detection system; supply/return airflow, static pressure and temperature split measured and recorded.
- City of Mission Viejo permit and inspection, plus Title 24 HERS verification by an independent rater: duct leakage passed on the first test.
The result
All three floors are now served by quiet, inverter-driven heat pumps for heating and cooling, with no more R-22 and no more gas furnaces in the attic. The new plenum and dampers balanced airflow between the remodeled second floor and the third floor, and the system passed HERS duct leakage testing on the first try. Both systems have deep MERV 15 filtration, overflow protection on every drain, Daikin One Touch thermostats with app control and a signed-off permit, and the homeowners got the Daikin rebate on both systems.
Project gallery
Equipment summary
| 1st floor system | Daikin FIT DH6VSA heat pump (3.5-ton) + DFVE air handler |
|---|---|
| 2nd and 3rd floors | Daikin FIT DH6VSA heat pump (4-ton) + DFVE air handler |
| Replaced | Two 20+ year-old Carrier systems (R-22 condensers and gas furnaces) |
| Efficiency | Up to 19 SEER2, inverter-driven variable-speed compressor |
| Refrigerant | R-32 |
| Indoor air quality | Daikin One Premium Air Cleaner (MERV 15 + catalyst insert), both systems |
| Controls | Daikin One Touch smart thermostats (2), remote control via the Daikin One Home app |
| Airflow | New supply plenum with balancing dampers, upper-floor system rebalanced |
| Line sets | Chemical flush, nitrogen purge, new filter driers, triple evacuation below 500 microns |
| Compliance | City of Mission Viejo permit; Title 24 HERS verification passed on the first test |
| Location / timing | Mission Viejo · September 2026 |
Still running R-22 equipment? MaksBuilder is a licensed HVAC contractor (CSLB #1095368) and Daikin Comfort Pro dealer serving Mission Viejo, Lake Forest and South Orange County. Itemized proposals and free in-home estimates: (949) 740-0410 · maksbuilder.com