COTO DE CAZA, CALIFORNIA AUGUST 2026

The upstairs system had stopped cooling. Downstairs, a second 30-year-old system was struggling in the summer heat. MaksBuilder replaced both with separate Daikin FIT heat pumps, rebuilt the attic ductwork and added MERV 15 filtration and UV equipment to each system.

Original outdoor condenser beside the home before replacement
BEFOREOriginal outdoor AC equipment in the side yard
Two new slim Daikin FIT outdoor heat pumps on separate pads
AFTERTwo Daikin FIT outdoor heat pumps installed on new pads
Systems replaced
2 heat pumps
System capacities
3 + 3.5 tons
Ductwork
Complete attic replacement
Air treatment
MERV 15 + UV on both
01 / THE BRIEF

Two aging systems.
Two different problems.

The Coto de Caza home still had its original HVAC equipment, both systems more than 30 years old. The upstairs unit had stopped working; downstairs, cooling was inadequate during a summer heat wave.

Undersized, worn attic ductwork also contributed to strong, noisy airflow on the first floor. The homeowners reported high electricity bills and wanted the ductwork addressed as part of the replacement—not simply two new outdoor units connected to the old runs.

02 / SYSTEM SELECTION

One Daikin FIT system for each floor

After inspecting the systems and duct runs, Maksym compared Carrier, Lennox and Daikin options with the homeowners. They chose two inverter-driven Daikin FIT heat pumps.

LEVEL 02 UPSTAIRS3-ton

Daikin FIT heat pump

Outdoor unit DH6VSA3610
Matched air handler DFVE36CP0300
Air handler location: attic

LEVEL 01 DOWNSTAIRS3.5-ton

Daikin FIT heat pump

Outdoor unit DH6VSA4210
Matched air handler DFVE42CP0300
Air handler location: garage closet

Variable-speed operation

Daikin FIT adjusts compressor output as demand changes. The series offers efficiency ratings up to 19 SEER2, depending on the matched system.

Rebuilt air distribution

All existing attic duct runs were replaced and sized using Manual D rather than reconnected to the new equipment.

Filtration and UV

Each system received a Daikin One Premium Air Cleaner with MERV 15 media and catalyst insert, plus UV air-treatment equipment.

03 / ON SITE

Installation and commissioning

New equipment and ductwork were installed in the attic, garage closet and side yard, followed by airflow, refrigerant and safety checks.

New Daikin FIT air handler being installed and wired in the attic
INSTALLATIONNew upstairs air handler in the attic
Original furnace and ducts before the attic retrofit
BEFOREOriginal attic equipment and ducts
Finished upstairs air handler with insulated plenum and ducts
AFTERFinished upstairs air handler and insulated ducts
  1. Remove the original systemsBoth indoor and outdoor systems were disconnected, removed and hauled away.
  2. Rebuild the attic ductworkNew R-6 insulated flexible ducts, Manual D sizing, sheet-metal plenums, take-offs and register boots; joints mechanically secured and sealed with UL 181 mastic, with compliant supports.
  3. Install refrigerant and control connectionsNew insulated copper line sets, control wiring and paintable exterior line-hide covers.
  4. Fit the indoor equipmentBoth air handlers received new condensate drains and traps, MERV 15 air cleaners and UV equipment.
  5. Set the outdoor heat pumpsBoth Daikin FIT units were installed on new pads with new disconnects.
  6. Test and commissionNitrogen pressure testing and triple vacuum before charging, followed by checks of refrigerant charge, safety controls, airflow, static pressure and temperature split.
  7. Complete required verificationThe permit was obtained and HERS testing completed under California Title 24.
  8. Protect the homeCloset and carpet protection, shoe covers indoors and cleanup at the end of each workday.
04 / THE OUTCOME

Cooling restored on both floors

The new systems cool the upstairs and downstairs spaces. The rebuilt ductwork addressed the previously noisy, uneven first-floor airflow. Both systems now have MERV 15 filtration and UV equipment.

Commissioning included airflow, static-pressure and temperature-split checks before handover.

“I knew from the moment he gave us the bid, that he was our man… he explained the pros and cons of all of them and then proceeded to give us a price for each so we could choose… They covered our large walk in closet with plastic and covered our carpets, always putting on shoe covers when in the house, leaving everything clean and neat at the end of the day… They deserve 10 stars!”

Patricia H. BBB review · August 2026
06 / PROJECT RECORD

Equipment and technical details

Installed models and work documented for this Coto de Caza retrofit.

Upstairs system Daikin FIT heat pump DH6VSA3610 (3-ton) + air handler DFVE36CP0300, attic
Downstairs system Daikin FIT heat pump DH6VSA4210 (3.5-ton) + air handler DFVE42CP0300, garage closet
Efficiency Up to 19 SEER2, inverter-driven variable-speed compressor
Refrigerant R-32
Ductwork Complete attic duct replacement: R-6 flex, Manual D sizing, UL 181 mastic
Indoor air quality Daikin One Premium Air Cleaner (MERV 15) + UV air purification, both systems
Other New line sets and line-hide covers, permit and HERS testing
Location / timing Coto de Caza · August 2026