COTO DE CAZA, CALIFORNIA AUGUST 2026
The upstairs system had stopped cooling. Downstairs, a second 30-year-old system was struggling in the summer heat. MaksBuilder replaced both with separate Daikin FIT heat pumps, rebuilt the attic ductwork and added MERV 15 filtration and UV equipment to each system.


- Systems replaced
- 2 heat pumps
- System capacities
- 3 + 3.5 tons
- Ductwork
- Complete attic replacement
- Air treatment
- MERV 15 + UV on both
Two aging systems.
Two different problems.
The Coto de Caza home still had its original HVAC equipment, both systems more than 30 years old. The upstairs unit had stopped working; downstairs, cooling was inadequate during a summer heat wave.
Undersized, worn attic ductwork also contributed to strong, noisy airflow on the first floor. The homeowners reported high electricity bills and wanted the ductwork addressed as part of the replacement—not simply two new outdoor units connected to the old runs.
One Daikin FIT system for each floor
After inspecting the systems and duct runs, Maksym compared Carrier, Lennox and Daikin options with the homeowners. They chose two inverter-driven Daikin FIT heat pumps.
Daikin FIT heat pump
Outdoor unit DH6VSA3610
Matched air handler DFVE36CP0300
Air handler location: attic
Daikin FIT heat pump
Outdoor unit DH6VSA4210
Matched air handler DFVE42CP0300
Air handler location: garage closet
Variable-speed operation
Daikin FIT adjusts compressor output as demand changes. The series offers efficiency ratings up to 19 SEER2, depending on the matched system.
Rebuilt air distribution
All existing attic duct runs were replaced and sized using Manual D rather than reconnected to the new equipment.
Filtration and UV
Each system received a Daikin One Premium Air Cleaner with MERV 15 media and catalyst insert, plus UV air-treatment equipment.
Installation and commissioning
New equipment and ductwork were installed in the attic, garage closet and side yard, followed by airflow, refrigerant and safety checks.



- Remove the original systemsBoth indoor and outdoor systems were disconnected, removed and hauled away.
- Rebuild the attic ductworkNew R-6 insulated flexible ducts, Manual D sizing, sheet-metal plenums, take-offs and register boots; joints mechanically secured and sealed with UL 181 mastic, with compliant supports.
- Install refrigerant and control connectionsNew insulated copper line sets, control wiring and paintable exterior line-hide covers.
- Fit the indoor equipmentBoth air handlers received new condensate drains and traps, MERV 15 air cleaners and UV equipment.
- Set the outdoor heat pumpsBoth Daikin FIT units were installed on new pads with new disconnects.
- Test and commissionNitrogen pressure testing and triple vacuum before charging, followed by checks of refrigerant charge, safety controls, airflow, static pressure and temperature split.
- Complete required verificationThe permit was obtained and HERS testing completed under California Title 24.
- Protect the homeCloset and carpet protection, shoe covers indoors and cleanup at the end of each workday.
Cooling restored on both floors
The new systems cool the upstairs and downstairs spaces. The rebuilt ductwork addressed the previously noisy, uneven first-floor airflow. Both systems now have MERV 15 filtration and UV equipment.
Commissioning included airflow, static-pressure and temperature-split checks before handover.
“I knew from the moment he gave us the bid, that he was our man… he explained the pros and cons of all of them and then proceeded to give us a price for each so we could choose… They covered our large walk in closet with plastic and covered our carpets, always putting on shoe covers when in the house, leaving everything clean and neat at the end of the day… They deserve 10 stars!”
A closer look at the work
Original attic ductwork, new insulated runs and the completed indoor and outdoor installations.





Equipment and technical details
Installed models and work documented for this Coto de Caza retrofit.
| Upstairs system | Daikin FIT heat pump DH6VSA3610 (3-ton) + air handler DFVE36CP0300, attic |
|---|---|
| Downstairs system | Daikin FIT heat pump DH6VSA4210 (3.5-ton) + air handler DFVE42CP0300, garage closet |
| Efficiency | Up to 19 SEER2, inverter-driven variable-speed compressor |
| Refrigerant | R-32 |
| Ductwork | Complete attic duct replacement: R-6 flex, Manual D sizing, UL 181 mastic |
| Indoor air quality | Daikin One Premium Air Cleaner (MERV 15) + UV air purification, both systems |
| Other | New line sets and line-hide covers, permit and HERS testing |
| Location / timing | Coto de Caza · August 2026 |
Replacing two aging HVAC systems?
Schedule a free in-home installation estimate with MaksBuilder. We can review the existing equipment, air distribution and options for your home.